9/7/17 – Procedure Violations

There are a number of actions that need to take place as you start up the plant and move to producing electricity. If you don’t perform these operations, you get dinged with a Procedure Violation!

  • Switch from Start-Up Transformer to Auxiliary Transformer
    • After the Generator is online and before Generator load is > 5%, switch from the Start-up Transformer to the Auxiliary Transformer.
  • Switching from Auxiliary Feedwater Pumps to Main Feed Pumps
    • Switch to the Main Feedwater Pumps when increasing above 10% Generator load
  • Steam Generator Levels
    • Before going above 0.1% Reactor Power, Steam Generator Levels must be above 50%
  • Accumulator Block Valve
    • Before going above 0.1% Reactor Power, unblock the Accumulator Block valve.
  • Permissive Blocks
    • Before going above 0.1% Reactor Power, disable the Permissive Blocks
  • Reactor Power Detection
    • Startup Range Detector enabled and Rx Power > 7.29e-03
    • Intermediate Range Detector and Rx Power < 3.48e-03
    • Intermediate Range Detector and Rx Power > 12.6
    • Power Range Detector and Rx Power < 0.0747
    • Startup / Intermediate / Power Range Detectors all off

ProcedureViolations